Standard
Rating : 1.5-20 AMPERE
Input Power : 125 VAC / 250 VAC /32 VDC
Dielectric Strength : 1500VAC / 1 Minute.
Interrupt Capacity : 125 VAC x 1000A, 250
VAC x 200A.
Insulation Resistance : >100 M¢G[
Calibration :
25°C
- 105% of Rated Current - Continuously Carried.
25°C
- Between 101% to 134%-May Trip or Not.
25°C
- 135% of Rated Current -Trip Within 1Hour.
25°C
- 200% of Rated Current -Trip Within 1Minute.
Approval:
2-18A 125 / 250 VAC
3A-15A 125VAC
2A-15A 125VAC / 250VAC / 32VDC
Contact Endurance : 125 VAC x 150% of Rated Current
-500 Cycles.
Reset : Manual Push Reset / Auto Reset.
Maximum Internal Resistance
|
Amp
|
Ohm
|
|
|
1.5A-2A
|
0.150
|
|
|
2.5A-3A
|
0.120
|
|
|
3.1A-4A
|
0.080
|
|
|
4.1A-5A
|
0.040
|
|
|
5.1A-6A
|
0.025
|
|
|
6.1A-7A
|
0.020
|
|
|
8.1A-9A
|
0.016
|
|
|
10.1A-11A
|
0.012
|
|
|
12.1A-13A
|
0.010
|
|
|
14.1A-16A
|
0.008
|
|
|
18.1A-20A
|
0.006
|
|
|